Wiring, Printed - Component
UL Certified
DOCUMENT:
ZPMV2.E232940Product Code (UL CCN):
ZPMV2Product CategoryThe Product Category, also known as the UL Category Description, describes the product classification under which an item or product is listed.
Wiring, Printed - Component
File NumberA code UL has assigned to identify and track this listing.
E232940
Model Number(s)Model numbers included in the listing. Multiple model numbers may indicate different products, different components within the products or both. This document also may not show all models included in the listing.
JVE-Y2, JVE-S1, JVE-R2, JVE-P2, JVE-I2, JVE-F2, JVE-02, JVE-S9, JVE-S7, JVE-T4, JVE-S3, JVE-S2, JVE-...
More
JVE-Y2
JVE-S1
JVE-R2
JVE-P2
JVE-I2
JVE-F2
JVE-02
JVE-S9
JVE-S7
JVE-T4
JVE-S3
JVE-S2
JVE-T9
JVE-T12
JVE-P4
JVE-S5
JVE-T3
JVE-M6
JVE-M8(Note2)
JVE-T8
JVE-S2A
JVE-T2
JVE-T11
JVE-T10
JVE-T1
JVE-S6
JVE-S4A&
JVE-S4(%)
JVE-T6
JVE-R4
JVE-M1
JVE-M4(%)(Note 3)
JVE-HY7
JVE-HY6
JVE-F4
JVE-D8
JVE-D2
JVE-H2
JVE-M2(note 1)
JVE-R3
JVE-T14
JVE-T13
JVE-HY5
JVE-T15
JVE-HY8
JVE-M12
JVE-S8
JVE-D4
JVE-M11(Note4)
JVE-M14(ASP1)(Note5)
Sec 2.10.5.5
Working Voltage: 1550 V
when Insulation Grade: Reinforced
Minimum Distance Through Insulation: 0.40 mm. When Insulation Grade: Basic
Minimum Distance Through Insulation: 0.15 mm.)
the minimum conductor width is 0.30mm and the minimum edge conductor width is 0.30mm. CEMENTED JOINT tested per UL60950-1
JVE-M4B (Note:When the external copper thickness is in the range of 102-170mic
JVE-S12(ASP1)
JVE-S13 (ASP 1)
JVE-M16 (ASP 1)
JVE-S11 (ASP 1)
JVE-T17 (ASP 1)
JVE-S19 (ASP 1) (Note6)
JVE-S17 (ASP1)
JVE-S14 (ASP 1) (Note8)
JVE-M18 (ASP 1)
JVE-S16 (ASP 1)
JVE-M13 (ASP 1) (Note7) (Note8)
JVE-S15 (ASP 1) (Note6)
JVE-M10 (When the external copper thickness is in the range of 102-204mic, the minimum conductor width is 0.30mm and the minimum edge conductor width is 0.30mm.)
JVE-M4A& (Note:CEMENTED JOINT tested per UL60950-1, Sec 2.10.5.5, Working Voltage: 1550 V, when Insulation Grade: Reinforced, Minimum Distance Through Insulation: 0.40 mm. When Insulation Grade: Basic, Minimum Distance Through Insulation: 0.15 mm.)
JVE-T5 (ASP 1)
JVE-T7 (ASP 1)
JVE-S10 (When the external copper thickness is in the range of 102-204mic, the minimum conductor width is 0.30mm and the minimum edge conductor width is 0.30mm.)
JVE-S18 (ASP 1)
JVE-M15 (ASP 1)
JVE-M13A (ASP 1) (Note8) (Note9)
Models
< BackCompanyThe Company that holds the listing with UL.
Shenzhen Jove Enterprise Ltd
GUIDE INFORMATION
Need More Information?
Looking for Guide Information documents and more? Product iQ offers professional level information and is free for most users.
Anyone can obtain information about the validity of a given certification by contacting the UL Customer Experience Center.
Phone number: 1-877-854-3577 — Email: [email protected]